Sign In | Join Free | My spintoband.com
spintoband.com
Yixing Haina Environmental Engineering Co.,ltd.
Yixing Haina Environmental Engineering Co.,Ltd Human Relies on Environment . Environment needs Human Protection
Home > Wet Gas Scrubber >

Coal Boiler and Kiln  Scrubber Systems For So2 Treatment , Air Pollution Scrubber System

Yixing Haina Environmental Engineering Co.,ltd.
Yixing Haina Environmental Engineering Co.,ltd.
Province/State: Jiangsu
Country/Region: China
Tel: 86-510-87838893
Contact Person:
Miss Jennifer Zhang

Coal Boiler and Kiln  Scrubber Systems For So2 Treatment , Air Pollution Scrubber System

Brand Name : HAINA
Model Number : LP
Certification : ISO9001:2008
Place of Origin : China
MOQ : 1 set
Price : USD 2000~5000/ set
Supply Ability : 10 sets/ week
Delivery Time : 20 work days
Packaging Details : 1. If the device is seperately transported, regular case would be used. 2. If the device is transported as a whole, it will be packed nude.
Product Name : Widely Furnace and Boiler Used Wet Gas Scrubber for SO2 Treatment
Material : Carbon Steel Plate
Application : Industrial Boiler
Resistance : <1200Pa
Inlet Gas Speed : 17-23m/s
Gas Temperature : 50-80 ℃
Liquid Gas Ratio : 2.5-4.0L/m³
Contact Now

Production Description


Main-vice Desulphurization Wet Scrubber is made of carbon steel and lined with granite. Several modules are separated and assembled at site. (Or made as a whole steel-made tower and lined with granite.) The gas after dedusting enters into the desulphurization tower, and the SO2 containing in the flue gas is purified due to neutralization reaction. The vice tower has the function of dehydration in order to protect the ID fan, flue and chimney that connected after the vice tower.



Principle of Operation


Desulphurization spray layer is based on the upper part of the tower, the absorption tower slurry circulating pump corresponding to each spray layer. The nozzle configuration of spray layer is simulated designed by professional software in order to ensure good contact with alkali and acid reverse gas reaction; and finally reach purification effects. Demister installs in the upper desulphurization tower, a total of two levels. The net is used to separate the entrainment of flue gas cloud droplets, and droplet concentration in flue gas export from mist eliminator is less than 75 mg/Nm3 (dry basis). At the same time, the equipment also has spray washing device to the tiny dust particles adhesion and desulphurization of flue gas crystallization on the demister system resistance increases.



Installation and Precautions


1.When installation, equipment should refer to general assembly drawing from the bottom to the top sequentially. it can also be installed according to the number of each section since there are numbers attached on tower when the equipment is delivered.2.When the base has been placed to the position, top flange washer should be covered 1-2cm thick furan resin daub from the second section, and then the uppers can be lift one by one.3.Installation of equipment inlet: orientation of inlet should be determined in advance (ensure the consistency between inlet center of device and the boiler outlet duct center so as to connect with air duct conveniently)

4. Please follow the above steps to install successively. After finishing water tank section, please enter into the device with ladder or scaffold and clear excess cement of cyclone muff, seam between internal section and section should be filled.

5. Please pay attention to the position of water feeding so as to connect the position of spray nozzle and pump.



Transportation



Points for Attention


Points for Attention
1

Please clean up settling tank regularly. Ash deposition will cause the incomplete precipitation of dust and desulfurization products. If impurity content of water which flows into clean water tank is too high, it will block pump and spray device so that desulfurization effect will be influenced.


2

Feed water flow control: Adjust water flow supply and control the water supply in allowed range. Do not bring liquid water into induced fan and chimney.


3

Boiler room operators should seriously record following information in time: the amount of alkali, PH value of water in tank, water addition, PH value of ash water and cleaning dust situation of depositing chamber.


4

Check whether the pump, fan and electric motor are heating, whether there is abnormal noise and whether there is seepage water of pump.


5

Check whether desulfurization products generate crystallizing, if crystallizing has been generated; please change circulating water in tank in case of clogging nozzle and affecting desulfurization effects.


6

Circulating water should be changed when blow is out in case that there is no water but burning.


7

Equipment failure: Firstly, please find the causes of the malfunction, if the problem can be solved individually, actions should be taken immediately, if the individual can not solve the problem, please inform the responsible officer and boiler operators as soon as possible. When stopping running the equipment for repair, the fan should be firstly turned off, and then the pump.




China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Coal Boiler and Kiln  Scrubber Systems For So2 Treatment , Air Pollution Scrubber System Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Yixing Haina Environmental Engineering Co.,ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0